Personal Alert Safety System Pass Device

Provisions in nfpa 1982.
Personal alert safety system pass device. Typically pass devices sense movement or lack of movement and activate a 95 decibel alarm signal if the lack of motion exceeds a specific time period. Get the 2018 edition of nfpa 1982 to stay up to date and protect lives. The personal alert safety system pass alarm was part of a scott pak breathing apparatus that was used in the recovery efforts after september 11 2001. Personal alert safety systems pass make it possible for emergency responders to signal for help if they get lost disoriented trapped injured or run out of breathing air while operating at an emergency.
Nfpa 1982 standard on personal alert safety systems pass. Smallest lightest and loudest standalone audible pass. A pass device personal alert safety system also known as a distress signal unit dsu or adsu automatic distress signal unit is a personal safety device used primarily by firefighters entering a hazardous or immediately dangerous to life and health environment such as a burning building the pass device sounds a loud 95 decibel audible alert to notify others in the area that the. Firefighters carry pass alarms to notify others if they have fallen or been trapped.
Worn on the belt or attached to a coat the pass alarm will begin beeping if the firefighter is no longer standing upright. Superpass 2 features. A personal alert safety system pass for lone workers is a protective equipment that allows its user to transmit an alert signal in case of a dangerous event or situation. Personal alert safety system pass devices are designed to signal for aid via an audible alarm.
Personal alert safety system pass devices were developed to protect us the firefighters from a wide range of potentially life threatening events that can occur on the fireground including. The alert signal form a lone worker pass device is automatically triggered the device detects an absence of movement for a prolonged period of time a fall a failed safety check etc or can be triggered manually by the. The alarm can also be activated manually. The loud audible alarm and flashing light indicators will alert other individuals on the scene of the situation so they can help to evacuate their coworkers.
The device includes 9 v battery for up to 100 hours of operation and an estimated 4 6 hours in full alarm mode. Standard on personal alert. National fire protection association. The standard specifies that the pass device will go into pre alarm mode after 20 seconds of inactivity and full alarm mode at 30 seconds of inactivity.
The loud alarm signal alerts other personnel that a firefighter has become incapacitated and it.